GBC7400 CHASSIS Quantity: 1
$4.99
» View Details
CS-607 Quantity: 1
$4.99
» View Details
GSFS 1331 WS Quantity: 1
$4.99
» View Details
SA2125/37B Quantity: 1
$4.99
» View Details
AWG 874 PL Quantity: 1
$4.99
» View Details
DFG 3360 BR Quantity: 1
$4.99
» View Details
VCR7000 Quantity: 1
$4.99
» View Details
582Z Quantity: 1
$4.99
» View Details
MC 056CD Quantity: 1
$4.99
» View Details
DS400FS Quantity: 1
$4.99
» View Details
7299C Quantity: 1
$4.99
» View Details
VTP75DSGK Quantity: 1
$4.99
» View Details
EV9DVD Quantity: 1
$4.99
» View Details
TF 117-IB Quantity: 1
$4.99
» View Details
SX-NH3 Quantity: 1
$4.99
» View Details
SLV-760HF Quantity: 1
$4.99
» View Details
LRC-288 Quantity: 1
$4.99
» View Details
SW3660/00 Quantity: 1
$4.99
» View Details
PDR240SQ Quantity: 1
$4.99
» View Details
CEX200VW1 Quantity: 1
$4.99
» View Details
LGR6638DZ0 Quantity: 1
$4.99
» View Details
34PW9525/12 Quantity: 1
$4.99
» View Details
790215_20616 Quantity: 1
$4.99
» View Details
AD70USR0 Quantity: 1
$4.99
» View Details
TRC8000Z Quantity: 1
$4.99
» View Details
KRA 1600/1 Quantity: 1
$4.99
» View Details
STV1403-T Quantity: 1
$4.99
» View Details
CP BASCULANTE L=1200 Quantity: 1
$4.99
» View Details
TC717 Quantity: 1
$4.99
» View Details
AW7150/20 Quantity: 1
$4.99
» View Details
KTRP19KGAL01 Quantity: 1
$4.99
» View Details
VLE760U Quantity: 1
$4.99
» View Details
A960N Quantity: 1
$4.99
» View Details
DD8696-A9 Quantity: 1
$4.99
» View Details
DVDQ50/782 Quantity: 1
$4.99
» View Details
KUDP02SRWH3 Quantity: 1
$4.99
» View Details
GS2SHAXMT00 Quantity: 1
$4.99
» View Details
Subtotal: $184.63
 
English Polski Spanish 
Buscar un manual
 

(p.Ej. AA-V20EG JVC, ZX-7 Sony)
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Productos
Información
Destacado
Inicio >> SHARP >> AH-AP24CE Manual de Servicio
 
 37 artículo(s) en Su carrito 

SHARP AH-AP24CE
Manual de Servicio


¡Twitee acerca de este producto y obtenga $1.00 de crédito en la tienda para uso!
  • Contiene diagramas del circuito
  • Descargable
  • Formato PDF
  • Manual completo
  • Idiomas: English
Precio: $4.99

Descripción del SHARP AH-AP24CE Manual de Servicio

Manual de servicio completo en formato digital (archivo PDF). Los manuales de servicio por lo general contienen diagramas de circuitos, tarjetas de circuitos impresos, consejos para reparación, diagramas de cableado, diagramas de bloque y lista de refacciones. El Manual de Servicio (a veces llamado Manual de Reparación) es usado principalmente por los técnicos.

Si tan solo quiere saber cómo utilizar su televisión, reproductor de vídeo, reproductor de mp3, etc. Quizá lo que necesita es el Manual del Propietario. Después de colocar la orden le enviaremos las instrucciones de descarga a su dirección de e-mail.

The manual is available in languages: English

Not yet ready
You must purchase it first

Opiniones de los clientes
No hay comentarios de productos.

TEXT_PDF_SNIPPET
AY-AP18CE AH-AP18CE AE-A18CE AU-A18CE

AY-AP24CE AH-AP24CE AE-A24CE AU-A24CE

4.

Hot-Keep This function automatically controls the on-off operation of the indoor fan motor in accordance during the heating operation, thereby preventing the air conditioner from delivering a cold air when the compressor is off. When the room temperature exceeds the thermostat line �H1�, the compressor is turned off, and the indoor fan motor is turned off after rotating at �HUL� for 30 seconds. 3 minutes and 10 seconds after turning off the compressor, the indoor fan motor is turned on for 3 minutes and 20 seconds. At 10 seconds after turning on the compressor, the indoor fan motor is turned on. The next compressor OFF time is for 3, 8 or more than 8 minutes according to the room temperature (the time increases with a rise of room temperature) when 3 minutes elapse after turning on the compessor.
3 min. Compressor ON 3 min.

6. Overheating protection system When overloading occurs during the heating operation, this system controls the outdoor fan motor according to the indoor pipe temperature to prevent the overloading of the compressor and restrain the rise in high pressure. When the indoor pipe temperature exceeds U1�C, the outdoor fan motor is turned off, and when the indoor pipe temperature falls U2�C, the outdoor fan motor turns on.
OFF U1 ON

U2

U1 and U2 are defferent by the time. 1 within 3 minutes 3 over 3 minutes

Figure Y-9 Table Y-3

OFF Indoor fan motor ON OFF
30sec. 30sec.

HUL

HUL

MODELS

Fan LIne U1

HH 1 2 54�C 54�C 52�C 53�C 54�C 54�C

HAH

HM 2 53�C 52�C 53�C 52�C

1 2 1 54�C 54�C 53�C 52�C 53�C 51�C 54�C 54�C 53�C 52�C 53�C 51�C HL

Thermo off

10sec.

time

10sec.

U2 U1

Figure Y-7 5. Preheat air flow This function is intended to prevent cold air from being discharged when the heating operation starts or when defrosting. When the indoor pipe temperature is below 29�C at the begining of the heat operation or after defrosting, the indoor fan motor stays. When the indoor pipe temperature gets higher than 29�C, the fan motor is turned on at speed �HUL� after compensation of starting. When the indoor pipe temperature exceeds 35�C, the specified fan speed is restored. When the indoor pipe temperature falls below 30�C, the fan speed shifts down to "HUL". And, when the indoor pipe temperature falls below 23�C, the fan motor turns off. Then, over 29�C , it turns on again at speed �HUL�.
35

U2 MODELS Fan LIne U1 U2 U1 U2

52�C 53�C HAL 1 2 52�C 52�C 50�C 51�C 52�C 52�C 50�C 51�C

HUL 2 52�C 51�C 52�C 51�C

1 2 1 52�C 52�C 52�C 50�C 51�C 50�C 52�C 52�C 52�C 50�C 51�C 50�C

30 29 24
Pipe temperature(�C)

OFF

UL

Preset Fan speed

UL

OFF UL

Figure Y-8
21

Quizás también quiera comprar

$4.99

AHAP24CE SHARP
Manual de Usuario

Manual del propietario completo en formato digital. El manual estará disponible para descarga como …
>
Parse Time: 1.577 - Number of Queries: 250 - Query Time: 1.043