AY-X10CR AE-X10CR AY-X10CR-N AE-X10CR-N
(1) Control for indoor freezing prevention If the temperature of the indoor heat exchanger stays below approximately 0°C for four minutes during cooling or dry, this control stops the compressor. Over 2�C the compressor will run again. (2) Control for cold air blowing prevention When heating begins, this control stops the indoor fan until the temperature of the indoor heat exchanger reaches 26°C. It also stops the fan if the temperature goes below 23°C during operation. (3) Indoor fan and operating frequency
Fan speed
12 11 10 9 8 7 6 5 4 3 2 1 0 j f h1 i 1 2 3 Operating frequency code 4 5 h2, g e d (Full power only) Dry
The indoor fan has 12 speeds, and changing is done in four stages, "Auto", "High", "Med", and "Low". The relations between the indoor fan speed, air quantity setting, operating frequency, and indoor heat exchanger are shown in the following charts. COOLING
11 10 9 8 7 6 5 4 3 2 1 OFF OFF 1 Low
Fan speed : High / Med / Low
1-3 Automatic operation The operating mode and temperature setting are determined by the room temperature and the external air temperature. The operating mode will changeover automatically with the following condition.
Outdoor temperature (°C) 34 Cooling (26�C)
High
Med
0
10
18 Cooling (24�C)
28
Heating Heating Heating
23456 Frequency cord 7 8 9
Fan speed
29
Cooling Cooling Cooling (26�C) (25�C) (24�C) (24�C) (23�C)
Cooling (25�C)
(Dry) (Room temperature (22�C) - 2°C)
21
Fan speed : Automatic 11 10 9 8 7 6 5
Room temperature (�C)
When the cooling operation only can use winter kit
4 3 2 1 OFF OFF 1 23456 Frequency cord 7 8 9
1. From cooling to heating Cooling mode will changeover to heating mode when condition of indoor temperature 1.7�C lower than the set temperature conditions for 5 minutes. 2. From heating to cooling Heating mode will change over to cooling mode when condition of indoor temperature 1.3�C higher than the set temperature conditions for 25 minutes under Hot keep condition. 3. When the set temperature is adjusted within the range of ±2�C by the remote control's key. ( ), the changeover judgement room temp. will also be shifted within the range of ±2�C. 1-4 ON-timer The ON-timer is set by pressing the ON-timer button. In order to attain the set temperature at the set time, the operation starting time is corrected by fuzzy computing one hour before the set time.
HEATING
Fan speed : High / Med / Low 12 11 10 9 8 7 6 5 4 3 2 1 OFF OFF 1 23456 Frequency cord 7 8 9 A B C High D-H Med D-H Low D-H C B A
Fan speed : Automatic
12 11 10 9 8 7 6 5 4 3 2 1 OFF
Fan speed
E, F, G, H
D
C
B A
OFF 1
23456 Frequency cord
7
8
9
A
B
C
13
|
|
|
> |
|