IC199 memory data NOTE FOR THE REPLACING OF MEMORY IC
Addreess 82 83 84 85 86 87 88 8A 8C 8D 91 From C8 CB D0 D3 D7 94 96 9C 55 57 60 To CC CF D3 D6 D9 96 98 9D 56 58 5F Change of MICON IC. Cause
How to Change memory data
1. Enter DATA SET mode by setting VOLUME to minimum. 2. Press both VOL. DOWN button on the set and Channel button (6) on the remote control for more than 2 seconds.
ADDRESS
DATA
INIT 00 00 CRT ON 0010
3. ADDRESS is now selected and should "blink". Using the VOL. +/- button on the remote, step through the ADDRESS until required ADDRESS to be changed is reached. 4. Press OK to select DATA. When DATA is selected, it will "blink". 5. Again, step through the DATA using VOL. +/- button until required DATA value has been selected. 6. Pressing OK will take you back to ADDRESS for further selection if necessary. 7. Repeat steps 3 to 6 until all data has been checked. 8. When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.