Adjustment procedure/conditions 1. Receive the GREEN-ONLY signal. Adjust the beam current to ~700 µA . 2. Degauss the CRT enough with the degausing coil. Note: Follow the Job Instruction Sheet to adjust the magnetic field. (Reference: page 3-5) 3. Maintain the purity magnet at the zero magnetic field and keep the static convergence roughly adjusted. 4. Observe the points a, b,as shown in Fig. 1-1 through the microscope. Adjust the landings to A rank requirement. 5. Orient the raster rotation to 0 eastward. 6. Tighten up the deflection coil screws. Tightening torque: 108 ± 20 N (11 ± 2 kgf) 7. Make sure the CRT corners landing meet the A rank requirements. If not, stick the magnet sheet to correct it. Note: This adjustment must be done after warming up the unit for 30 minutes or longer with a beam current over 700 µA. Note: Set to service mode by remote controller then press factory process R/C RGB key to change to RGB mono colour mode. * For the following colours press R/C RGB(Hex 7E) key to change.
GREEN ONLY BLUE ONLY Signal-colour screen cleared RED ONLY
Waveform and others
a
b
30mm
Fig. 1-1
30mm
A
B A=B
Fig. 1-2
Rank "A" (on the right of the CRT)
A
B A=B
Fig. 1-3
Rank "A" (on the left of the CRT)
* Press R/C RGB key for 1 second in NORMAL MODE, the colour will change to RGB mono colour mode.